The clinical application of vertical cylindrical mesh implants in 35 patients for surgical treatment of diseases and injuries of their cervical spine was analysed. This technology is an effective method for restoration of the carrying capacity of vertebral motor segments regardless of the length of the anterior cervical interbody fusion.
References
- Барыш А. Е. Окципитоцервикоспондилодез в хирургическом лечении повреждений и заболеваний верхнешейного отдела позвоночника / А. Е. Барыш // Ортопед. травматол. — 2004. — № 4. — С. 40–47. — ISSN 0030-5987.
- Барыш А. Е. Обоснование новой технологии переднего межтелового цервикоспондилодеза с помощью гибридных металлокерамических фиксирующих устройств / А. Е. Барыш // Ортопед. травматол. — 2005. — № 2. — C. 15–21. — ISSN 0030-5987.
- Барыш А. Е. Современный подход к клинической оценке результатов хирургического лечения заболеваний и повреждений шейного отдела позвоночника в практике ортопеда-травматолога / А. Е. Барыш // Междунар. мед. журнал. — 2007. — № 2. — С. 75–81.
- Пат. 58900 А Україна, МПК7 А 61 F 2/44. Ендопротез сегмента хребта / Корж М. О., Бариш О. Є., Лук’янченко В. В., Макгоуан Д. П.; № 2002119196; заявл. 19.11.2002; опубл. 15.08.2003, Бюл. № 8.
- Корж Н. А. Нестабильность шейного отдела позвоночника: дисс. ... д-ра мед. наук: 14.01.21. / Корж Николай Алексеевич. — Х., 1985. — 433 с.
- Пат. 77910 (С2) Україна, МПК С 23 С 4/02. Спосіб детонаційного нанесення керамічного покриття на металеві вироби, переважно із титанових сплавів / Лук’янченко В.В., Власенко В.М.; заявник і патентовласник Товариство з об¬меженою відповідальністю «Інмайстерс». — № а200510623; заявл. 10.11.2005; опубл. 15.01.2007, Бюл. № 1.
- Хiрургiчне лiкування переломо-вивихiв в шийному вiддiлi хребта з застосуванням кейджа та гiдроксилапатитної кераміки / В. М. Шимон, М. М. Василинець, А. А. Мезiв та ін. // Травма. — 2009. — Т. 10, № 3. — С. 339–342.
- Шотурсунов Ш. Ш. Передняя интеркорпоральная стабилизация шейного отдела позвоночника титановыми кейджами / Ш. Ш. Шотурсунов, Р.Р. Рафиков: материалы Междунар. конф., посвящ. 100-летию ГУ «Институт патологии позвоночника и суставов им. проф. М.И. Ситенко АМН Украины» [«Актуальные проблемы артрологии и вер-тебрологии»]; АМН Украины, МЗ Украины. — Харьков, 2007. — С. 118–120.
- Bagby G. W. Artrodesis by the distraction-compression method using a stainless steel implant / G. W. Bagby // Orthopaedics. — 1988. — Vol. 11. — P. 931–934.
- Efficacy and safety of the use of titanium mesh cages and anterior cervical plates for interbody fusion after anterior cervical corpectomy / H. C. Chuang, D. Y. Cho, C. S. Chang et al. // Surg. Neurol. — 2006. — Vol. 65, № 5. — P. 464–471.
- Use of cylindrical titanium mesh and locking plates in anterior cervical fusion / K. Das, W. T. Couldwell, G. Sava, R. F. Taddonio // J. Neurosurg. (Spine 1). — 2001. — Vol. 94. — P. 174–177.
- Daubs M. D. Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating / M.D. Daubs // Spine. — 2005. — Vol. 30. — P. 1402–1406.
- Grob D. Titanium mesh cages (TMC) in spine surgery / D. Grob, S. Daehn, A. F. Mannion // Eur. Spine J. — 2005. — Vol. 14, № 3. — P. 211–221.
- Harms J. Instrumented spinal surgery; principles and technigue / J. Harms, G. Tabasso. — Stuttgart-New York: Thieme, 1999. — 198 p.
- An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density / K. Hasegawa, M. Abe, T. Washio, T. Hara // Spine. — 2001. — Vol. 26, № 8. — P. 957–963.
- Pitfalls of anterior cervical fusion using titanium mesh and local autograft / M. Kanayama, T. Hashimoto, K. Shigenobu et al. // J. Spinal Disord. Tech. — 2003. — Vol. 16, № 6. — P. 513–518.
- Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion / T.-H. Lim, H. Kwon, C.-H. Jeon et al. // Spine. — 2001. — Vol. 26, № 8. — P. 951-956.
- Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical corpectomy / H. Nakase, Y.S. Park, H. Kimura et al. // J. Spinal Disord. Tech. — 2006. — Vol. 19, № 5. — P. 353–357.
- Narotam P.K. Titanium mesh cages for cervical spine stabilization after corpectomy: a clinical and radiological study / P. K. Narotam, S. M. Pauley, G. J. McGinn // J. Neurosurg. — 2003. — Vol. 99, Suppl. 2. — P. 172–180.
- Pat. 4,820,305 United States, Int. Cl.4 A 61 F 2/28; A 61 F 2/44. Place holder, in particular for a vertebra body / Jurgen Harms, Lutz Biedermann; № 115,178; filed Oct. 30, 1987; public. Apr. 11, 1989.
- Pat. 6,585,770 B1 United States, Int. Cl.7 A 61 F 2/44. Devices for supporting bony structures / John L. White, Eddie F. Ray, John Stewart Young; № 09/692,530; filed Oct. 19, 2000; public. Jul. 1, 2003.
- Cages: design and concepts / T. Steffen, A. Tsantrizos et al. // Euro Spine. — 2000. — Vol. 9, № 7. — P. 5089–5094.
- Thalgott J. S. Single stage anterior cervical reconstruction with titanium mesh cages, local bone graft, and anterior plating / J. S. Thalgott, C. Xiongsheng, J.M. Giuffre // Spine. — 2003. — Vol. 3, № 4. — P. 294–300.
- Expandable cage for cervical spine reconstruction / H. Y. Zhang, I. Thongtrangan, H. Le et al. // J. Korean Neurosurg. Soc. — 2005. — Vol. 38, № 6. — P. 435–441.
Downloads
How to Cite
Issue
Section
License
Copyright (c) 2014 Oleksandr Barysh, Ruslan Buznytsky
This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors retain the right of authorship of their manuscript and pass the journal the right of the first publication of this article, which automatically become available from the date of publication under the terms of Creative Commons Attribution License, which allows others to freely distribute the published manuscript with mandatory linking to authors of the original research and the first publication of this one in this journal.
Authors have the right to enter into a separate supplemental agreement on the additional non-exclusive distribution of manuscript in the form in which it was published by the journal (i.e. to put work in electronic storage of an institution or publish as a part of the book) while maintaining the reference to the first publication of the manuscript in this journal.
The editorial policy of the journal allows authors and encourages manuscript accommodation online (i.e. in storage of an institution or on the personal websites) as before submission of the manuscript to the editorial office, and during its editorial processing because it contributes to productive scientific discussion and positively affects the efficiency and dynamics of the published manuscript citation (see The Effect of Open Access).