Bone morphology around implants with a ceramic coating and different surface topography
DOI:
https://doi.org/10.15674/0030-59872009138-44Keywords:
fusion, implants, morphologyAbstract
An experimental histomorphological study of the influence, exerted on the bone tissue of laboratory animals by different variants of the topography of the contact surface of 4 groups of 24 titanium implants, including those with a porous aluminium-oxide ceramic coating, was conducted. It was revealed that the character of the implant contact surface produced its effect on the strength of its connection with the bone, while titanium implants with a limited contact and porous ceramic aluminium-oxide coating demonstrated better integrative properties versus implants with a polished contact surface.
References
- Анкин Л.Н. Биологическая концепция остеосинтеза по АО / Л.Н. Анкин // Margo Anterior. — 1998. — № 6. — C. 1–3.
- Бублик Л.О. Ускладнені ушкодження шийного відділу хребта (діагностика, лікування та прогнозування у гострому та ранньому періодах травми): автореф. дис. на здобуття наук. ступеня докт. мед. наук: спец. 14.01.05 «Нейрохірургія» / Л.О. Бублик. — К., 2004. — 40 с.
- Корж Н.А. Новая технология передней межтеловой фиксации шейных позвонков пластинами / Н.А. Корж, А.Е. Барыш, Г.Х. Грунтовский, В.В. Лукьянченко // Травма. — 2004. — Т. 5, № 3. — С. 250–252.
- Корж Н.А. Передний межтеловой спондилодез пластинами в хирургическом лечении повреждений и заболеваний шейного отдела позвоночника / Н.А. Корж, А.Е. Барыш // Вісн. ортопедії, травматології та протезування. — 2005. — № 1. — С. 67–69.
- Корж Н.А. Имплантационные материалы и остеогенез. Роль биологической фиксации и остеоинтеграции в реконструкции кости / Н.А. Корж, Л.А. Кладченко, С.В. Малышкина, И.Б. Тимченко // Ортопед. травматол. — 2005. — № 4. — С.118–127.
- Корж Н.А. Первый опыт накостного остеосинтеза несросшихся переломов длинных костей титановыми пластинами с керамическим напылением / Н.А. Корж, Е.М. Мателенок, В.В. Лукьянченко // Ортопед. травматол. — 2008. — № 2. — С. 63–66.
- Лоскутов А.Е. Биомеханическое обоснование новой конструкции пластины с ограниченным контактом / А.Е. Лоскутов, И.И. Жердев, В.Л. Красовский, А.Н. Кондрашов // Ортопед. травматол. — 2002. — № 2. — С. 105-107.
- Пат. 57663 A UA, A 61B17/58. Пристрій для остеосинтезу, переважно спондилодезу / М.О. Корж, О.Є. Бариш, В.В. Лук’янченко. — № 2002107851; заявл. 03.10.2002; опубл. 16.06.2003, Бюл. № 6.
- Пат. 77910 С2 С23С4/02. Спосіб детонаційного нанесення керамічного покриття на металеві вироби, переважно із титанових сплавів / В.В. Лук’янченко, В.М. Власенко. — № 200510623; заявл. 10.11.2005; опубл. 15.01.2007, Бюл. № 1.
- Саркисов Д.С. Микроскопическая техника / Д.С. Саркисов, Ю.Л. Перова. — М.: Медицина, 1996. — 542 с.
- Перспективность использования пористых и керамических покрытий для улучшения интеграции имплантатов с костной тканью: материалы Междунар. науч.-практ. конф. [«Морфофункциональные аспекты регенерации и адаптационной дифференцировки структурных компонентов опорно-двигательного аппарата в условиях механических воздействий»], (Курган, 20-21 окт. 2004 г.) / ГУ РНЦ «ВТО» им. акад. Г.А. Илизарова. — Курган: ГУ РНЦ «ВТО» им. акад. Г.А. Илизарова. — С. 174–176.
- European convention for the protection of vertebrate animals used for experimental and other scientific purposes: Counci l of Europe 18.03.1986. — Strasbourg, 1986. — 52 p.
- Le Guehennec L. Histomorphometric analysis of th e osteointegrati on of four different im plant surfac es in th e femoral epiphy ses of rabbit s / L. Le Guehennec, E. Goyenvalle, M.A. Lopez-Hereida [et al.] // Clin. Oral Implants Res. — 2008. — Vol. 19, № 11. — P. 1103–1110.
- Narayanan R. Calcium phosphate-based coatings on titanium and it s alloys / R. Narayanan, S.K. Seshadri, T.Y. Kwon, K.H. Kim // J. Biomed. Mat at er. Res. B. Appl. Matater. — 2008. — Vol. 85, № 1. — P. 279–299.
- Pesskovа V. The influence of implant surface properties on cell adhesion and proliferation / V. Pesskovа, D. Kubiec, H. Hulejov, L. Himm lovа // J. Mat er. Sci . Mat er. Med. — 2007. — Vol. 18, № 3. — P. 465–473.
- Sandеn B. Improved extraction torque of hydroxyapatitecoated pedicle screws / B. Sandеn, C. Olerud, C. Johansson, S. Larsson // Eur. Spine J. — 2000. — Vol. 9, № 6. — P. 534–537.
- Spivak J.M. Use of hydroxyapatite in spine surgery / J.M. Spivak, A. Hasharony // Eur. Spine J. — 2001. — Vol. 10 (Suppl.). — Р. 197–204.
Downloads
How to Cite
Issue
Section
License
Copyright (c) 2014 Oleksandr Barysh, Ninel Diedukh

This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors retain the right of authorship of their manuscript and pass the journal the right of the first publication of this article, which automatically become available from the date of publication under the terms of Creative Commons Attribution License, which allows others to freely distribute the published manuscript with mandatory linking to authors of the original research and the first publication of this one in this journal.
Authors have the right to enter into a separate supplemental agreement on the additional non-exclusive distribution of manuscript in the form in which it was published by the journal (i.e. to put work in electronic storage of an institution or publish as a part of the book) while maintaining the reference to the first publication of the manuscript in this journal.
The editorial policy of the journal allows authors and encourages manuscript accommodation online (i.e. in storage of an institution or on the personal websites) as before submission of the manuscript to the editorial office, and during its editorial processing because it contributes to productive scientific discussion and positively affects the efficiency and dynamics of the published manuscript citation (see The Effect of Open Access).