Insertion of transpedicular screws in the lumbar spine with use of computed navigation

Authors

  • Oleksandr Beletskiy
  • Andrey Mazurenka
  • Sergey Makarevich
  • Sergey Zaretskiy
  • Anatoliy Petrenko
  • Yosyp Voronovich
  • Sergey Yurchenko

DOI:

https://doi.org/10.15674/0030-59872010389-95

Keywords:

transpedicular fixing, lumbar spine, computed surgical navigation

Abstract

Transpedicular fixing is widely used in spinal surgery. But the traditional control techniques, such as fluoroscopy and visual anatomical reference points for positioning screws, do not exclude complications. The use of computed navigation systems makes it possible to solve this problem. A system with involvement of preoperative computed tomography and intraoperative fluoroscopy makes it possible to monitor instruments relative to anatomical elements of the vertebral column in the real-time mode. Computed surgical navigation was employed in the process of intervention on the lumbar spine in 112 patients. The operations were performed on 52 patients for spondylolisthesis, 31 for degenerative stenosis, and 29 for injuries of the lumbar spine. Data of preliminary CT scanning) were used in 93 cases and those of intraoperative fluoroscopy “FluoroNav” program in 21. In order to reveal the position of screws in the postoperative period, all the patients underwent CT. In 109 cases, no injuries of the cortical plate of the arch root were found out and the position of screws was regarded as correct. Three cases developed an injury on the medial wall of the arch root: “FluoroNav” program was used in two of them and “FluoroMerge” program in one. In all three cases, revision operations were made to reinsert screws. No neurological postoperative complications (appearance of new disorders or aggravation of the available ones) were observed. The positioning of 6 screws from the moment of fixation of a reference frame to the positioning of the last screw lasted 30 minutes. Computed navigation made it possible to position transpedicular screws with high precision, thereby minimizing the risk of operation-dependent complications. Besides, the surgical procedure duration and the number of made roentgenograms become reduced.

References

  1. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement [Text] / J. N. Weinstein, K. F. Spratt, D. Spengler et al. // Spine. — 1988. — Vol. 13. — P. 1012–1018.
  2. Gertzbein S. D. Accuracy of pedicle screw placement in vivo [Text] / S. D. Gertzbein, S. Robbins // Spine. — 1990. — Vol. 15. — P. 11–14.
  3. Blumenthal S. Complications of the Wiltse pedicle screw fixation system [Text] / S. Blumenthal, K. Gill // Spine. — 1993. — Vol. 18. — P. 1867–1871.
  4. Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography [Text] / G. Farber, H. Place, R. Mazur et al. // Spine. — 1995. — Vol. 20. — P. 1494–1499.
  5. Accuracy of pedicle screw placement in lumbar vertebrae [Text] / W. H. M. Castro, H. Halm, J. Jerosch et al. // Spine. — 1996. — Vol. 21. — P. 1320–1324.
  6. Ferrick M. R. Reliability of roentgenographic evaluation of pedicle screw position [Text] / M. R. Ferrick, J. M. Kowalski, E. D. Simmons Jr. // Spine. — 1997. — Vol. 22. — P. 1249–1259.
  7. Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography [Text] / G. S. Sapkas, S. A. Papadakis, D. P. Stathakopoulos et al. // Spine. — 1999. — Vol. 24. — P. 1926–1929.
  8. Комплексное обследование больных и тактика внутренней стабилизации при стенозах и деформациях поясничного отдела позвоночника [Текст]: материалы научно-практ. конф. «Организация нейротравматологической помощи при спинальной травме». — Минск, 2004. — С. 75–76.
  9. Accuracy of computer-assisted pedicle screw placement [Text] / O. Schwarzenbach, U. Berlemann, B. Jost et al. // Spine. — 1997. — Vol. 22. — P. 452–458.
  10. Computer-assisted pedicle screw fixation [Text] / L. P. Amiot, H. Labelle, M. Sati et al. // Spine. — 1995. — Vol. 20. — P. 1208–1212.
  11. Computer-assisted pedicle screw insertion [Text] / Ph. Merloz, Ch. Huberson, J. Tonnetti et al. // Techniques in Orthopaedics. — 2003. — Vol. 18(2). — P. 149–159.
  12. Verma R. A meta-synthesis and meta-analysis of the functional outcome of computer assisted pedicle screw placement [Text] / R. Verma, K. Haendlmayer, R. Phillips, A. Mohsen // Suomen Ortopedia ja Traumatologia. — 2008. — Vol. 31. — P. 162–167.
  13. Спинальные навигационные станции: современные возможности и перспективы развития [Текст]: материалы научной конференции, посвященной 40-летию отделения патологии позвоночника «Хирургия позвоночника — полный спектр». — Москва, 2007. — С. 349–350.
  14. Опыт использования компьютерной навигации при транспедикулярной стабилизации поясничного отдела позвоночника [Текст] / А. В. Белецкий, А. Н. Мазуренко, С. В. Макаревич и др. // Медицинские новости. — 2010. — № 3. — С. 47–52.
  15. Weise L. Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system [Text] / L. Weise, O. Suess, T. Picht, T. Kombos // Medical Devices: Evidence and Research. — 2008. — Vol. 9. — P. 33–39.

How to Cite

Beletskiy, O., Mazurenka, A., Makarevich, S., Zaretskiy, S., Petrenko, A., Voronovich, Y., & Yurchenko, S. (2010). Insertion of transpedicular screws in the lumbar spine with use of computed navigation. ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS, (3), 89–95. https://doi.org/10.15674/0030-59872010389-95

Issue

Section

ORIGINAL ARTICLES